|
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
|
| Volume 187 - Issue 152 |
| Published: November 2026 |
| Authors: Divya T L, Chandrani C, Chiranjeevi R, B R Lohith Raj |
10.5120/ijca09ba8cdae08c
|
Divya T L, Chandrani C, Chiranjeevi R, B R Lohith Raj . Seven Layer Smart Subsea Pipeline Structure for Detection of Pinhole Leaks and Autonomous Deep Sea Functioning. International Journal of Computer Applications. 187, 152 (November 2026), 45-56. DOI=10.5120/ijca09ba8cdae08c
@article{ 10.5120/ijca09ba8cdae08c,
author = { Divya T L,Chandrani C,Chiranjeevi R,B R Lohith Raj },
title = { Seven Layer Smart Subsea Pipeline Structure for Detection of Pinhole Leaks and Autonomous Deep Sea Functioning },
journal = { International Journal of Computer Applications },
year = { 2026 },
volume = { 187 },
number = { 152 },
pages = { 45-56 },
doi = { 10.5120/ijca09ba8cdae08c },
publisher = { Foundation of Computer Science (FCS), NY, USA }
}
%0 Journal Article
%D 2026
%A Divya T L
%A Chandrani C
%A Chiranjeevi R
%A B R Lohith Raj
%T Seven Layer Smart Subsea Pipeline Structure for Detection of Pinhole Leaks and Autonomous Deep Sea Functioning%T
%J International Journal of Computer Applications
%V 187
%N 152
%P 45-56
%R 10.5120/ijca09ba8cdae08c
%I Foundation of Computer Science (FCS), NY, USA
Tiny pinhole leaks in deep-sea crude oil pipelines produce signals that are difficult to separate from normal pressure and flow fluctuations. This paper proposes a seven-layer smart subsea pipeline that combines pressure damping and protection, a corrosion-resistant structure, pressure and vibration sensing, acoustic detection, hybrid self-healing, redundant fibre-optic communication and hybrid power generation. The architecture is evaluated with a physics-based Python simulation covering pipeline flow, orifice leakage, sensor-signal modelling and two-phase healing kinetics. For a 50 km pipeline with a 0.5 m bore at 3,000 m depth, the external hydrostatic pressure is 301.66 bar and a 0.5 mm pinhole leaks 0.01299 L/s, or 0.00441% of the pipeline flow. Over ten minutes, cumulative leakage falls from 7.795 L without healing to 1.629 L with healing, a simulated reduction of 79.1%. A scenario analysis over pinhole diameter, healing efficiency, healing onset and depth, together with a Random Forest sensor-fusion classifier assessed by 10-fold cross-validation, extends the baseline result. Selected parameters are compared with 5,959 incidents in the U.S. PHMSA hazardous-liquid database (2010–2026); this gives real-world context but is not physical validation. Experimental testing is required before any physical implementation.